Product Details
- Voltage12 VDC
- Temperature Range-40 to 160 °F
Description
The Beckett GeniSys® 7556 Oil Burner Control is a potted (for high
moisture environments) 12 VDC primary safety control for oil burners
used on pressure washers, road stripers, crack sealers, hot patchers,
and asphalt distributors, to name a few examples. The GeniSys® 7556 is
used with a suitable cad cell flame sensor to control the oil burner
motor, igniter, and optional solenoid valve. It can provide interrupted
or intermittent duty ignition, and it has a 15 second lockout time.
- Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat.
- Valve-on delay / motor-off delay — field-programmable with Beckett GeniSys® Contractor Tool.
- Epoxy potted for moisture resistance.
- Welded relay protection with redundant motor relays.
- High ambient temperature rating.
- Alarm output enables visual or audio indication of flame failure and lock out condition.
- Interrupted ignition.
- Relight function.
- Fused protection.
- 15 second lockout time.
- Communication port.
Inputs
- Voltage: 12 VDC nominal (11 to 16 VDC).
- Current: 160 mA nominal (500 mA max at 16 VDC).
- Enable Load: 40mA at 12 VDC.
- Motor: 12 VDC, 20 full load amps (FLA), 100 locked rotor amps (LRA).
- Igniter: 12 VDC, 5 A.
- Solenoid Valve: 12 VDC, 2 A.
- Lockout Alarm: 12 VDC, 2 A.
- Valve On Delay: 0 seconds.
- Motor Off Delay: 0 seconds.