Product Details
- Voltage24 v
Description
These models are designed to provide combustion air for appliances when
direct connection to the burner is not possible (when the appliance is
located in a confined space). According to NFPA 54 and NFPA 31, an
engineered system such as a CAS-3, 4, 6 or 7 may be used to overcome the
lack of air in a confined space. The CAS-3 is designed for use with oil
appliances. The CAS-4 is for use with gas appliances with 24 VAC gas
valve controls. The CAS-4MV is for use with 750mV power pile gas
appliances. Each is designed for optimum safety and includes a proving
device that won?t allow the burner to engage without the Fan-in-a-Can®
operating. Multiple units or additional controls are required for
multiple appliance installations. Each is equipped with a two speed
control for enhanced versatility.
- Motorized Blower.
- 4" Galvanized Intake Air Hood.
- (2) Mounting Brackets to secure CAS to wall.
- (2) wire conduit connectors.
- 6" x 4" Pipe Reducer Fitting.
- 6" Orifice Ring.
- High/Low Motor Speed Switch.
Note: only use for Gas systems up to 280,000 BTU.