Product Details
- Size3/4 x 3/4 in
- Connection TypeNPT
- Temperature Range (F)-40 to 175 °F
- Fuel TypeNatural Gas
- Mount0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Max Pressure (PSI)1/2 PSI
- Voltage (v)24 v
- Hertz (HZ)50/60 Hz
Description
3/4" NPT x 3/4" NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with standard opening and 3.5" wc pressure regulator setting.
Includes: (2) 3/4" x 1/2" reducer bushings and an LP conversion kit.
Licensed Contractor Required: This product must be installed by a qualified/licensed contractor and set up with properly calibrated combustion test equipment. Failure to comply with this could result in substantial property damage, severe personal injury or death.
- These controls communicate directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.
- They also interface with the 208907 Terminal Board, providing compatibility with power stealing thermostats. Or, they directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
- When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.
- The SV9541 and SV9641 Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.
- Flame Sense: Two Rod
- Type of Gas: Natural
- Ignition System Type: Intermittent Hot Surface Pilot Ignition
- Ignition Sequence: Intermittent Pilot
- Ignition Source: Pilot
- Ignition Trials To Lockout: Continuous retry
- PrePurge: 15 seconds
- Body Pattern: Straight-through
- Opening Characteristics (standard, step): Standard Opening
- Control Voltage (Thermostat or other call for heat): 24 Vac
- Ignition Trial Time (sec): 90 Sec
- Electrical Ratings: 24 Vac
- Frequency: 60 Hz
- Frequency: 50 Hz
- Flame Failure Response Time (sec): 1.6 sec @ 3 µA
- Ambient Temperature Range (F): -40 F to +175 F
- Ambient Temperature Range (C): -40 C to +79 C
- Dimensions (in.): 3.2 in. wide x 4.9 in. high x 4.1 in. long
- Dimensions (mm): 81 mm wide x 124 mm high x 104 mm longPressure Regulator Setting (psi): 3.5 in. wc
- Pressure Regulator Setting (kPa): 0.87 kPa
- Pressure Ratings (psi): 1/2 psi
- Pressure Ratings (kPa): 3.5 kPa
- Inlet/Outlet Size (in.): 3/4 in. NPT x 3/4 in. NPT.
- Maximum Capacity (ft³/hr): 415 ft³/hr
- Maximum Capacity (m³/hr): 11.8 m³/hr
- Minimum Capacity (ft³/hr): 30 ft³/hr
- Minimum Capacity (m³/hr): 0.8 m³/hr
- Maximum Capacity at 1 in. P.D. (ft³/hr): 300 ft³/hr
- Maximum Capacity at 1 in. P.D. (m³/hr): 8.5 m³/hr
- Pressure Tapping: 1/8 in. - NPT
- Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Pilot Gas Outlet: Yes
- Tradeline Value: Super Tradeline