- Size1/2 x 1/2 in
- Temperature Range0 to 175 °F
- Fuel TypeNatural Gas
- Capacity (BTU)150000 BTU
- Max Pressure1/2 PSI
- Voltage24 VAC
- Hertz60 Hz
Description
Licensed Contractor Required: This product must be installed by a qualified/licensed contractor and set up with properly calibrated combustion test equipment. Failure to comply with this could result in substantial property damage, severe personal injury or death.
- Combination gas controls for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances with capacities from 20 to 200 cfh
- Controls include manual valve, two automatic operators, and pressure regulator
- Provide two automatic valves
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends
- Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted
- Meets codes requiring dual safety shutoff
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves
- Adjustments and wiring connections are accessible from top of the control
- ON-OFF lighting sequence
- Description: 24 Vac Dual Direct Ignition Gas Valve with 1/2 in. x 1/2 in. inlet/outlet, standard opening and 3.5 in. wc pressure regulator setting
- Type: Single Stage
- Ignition Type: Direct Ignition
- Type of Gas: Natural
- Inlet/Outlet Size (in.): 1/2 in. x 1/2 in.
- Body Pattern: Straight-through
- Opening Characteristics: Standard
- Capacity @ 1 in. p.d.: 150,000 BTU/hr; 20,000 BTU/hr minimum
- Pressure Ratings (psi): 1/2 psi
- Pressure Ratings (kPa): 3.5 kPa
- Pressure Regulator Setting (psi): 3.5 in. wc
- Pressure Regulator Setting (kPa): 0.87 kPa
- Pressure Tapping: 1/8 in. NPT with plug
- Electrical Connections: 1/4 in. quick-connect male terminals
- Electrical Ratings: 24 Vac
- Frequency: 60 Hz
- Anticipator Setting: 0.5 A
- Temperature Range (F): 0 F to 175 F
- Temperature Range (C): -18 C to +79 C
- Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically
- Dimensions (in.): 4 15/16 in. high x 4 1/8 in. wide x 2 11/16 in. deep
- Dimensions (mm): 125 mm high x 104 mm wide x 69 mm deep
- Includes: Natural to LP Conversion Kit, one 1/2" x 3/8" reducer bushing, one 3/4" straight flange
- Approvals, American Gas Association IAS: AGA Design Certified: File No. L2025006
- Approvals, Canadian Gas Association: CGA Design Certified: File No. L2025006
- Approvals, Underwriters Laboratories Inc: UL Component Recognized