null
In Stock
Honeywell

Honeywell RA832A1066/U; RA832A1066 Switching Relay (120v, Zones: 2)

No reviews yet Write a Review
$129.44
Honeywell RA832A1066/U; RA832A1066 Switching Relay (120v, Zones: 2)
Honeywell RA832A1066/U; RA832A1066 Switching Relay (120v, Zones: 2)
Honeywell RA832A1066/U; RA832A1066 Switching Relay (120v, Zones: 2)
Ships in 1 business day via UPS
SKU:
PSD5MWB6M2KK
MPN:
RA832A1066, RA832A1066/U
Current Stock:

Frequently Bought Together:

Honeywell RA832A1066/U; RA832A1066 Switching Relay (120v, Zones: 2)
Inc. Tax
Ex. Tax

Product Details

  • Voltage120 v
  • Zones2
  • Amperage7.4 A

Description

Provides intermediate switching of a line voltage device from a low voltage controller.
  • Integral transformer provides low voltage power for control circuit.
  • The RA832A is a tpst relay. One relay pole is designed for low voltage or millivoltage (Powerpile) auxiliary load. Two other relay poles are for line voltage loads.
  • Switching Relay with internal transformer, for switching two line voltage loads having a common power source.
  • Application Provide intermediate switching of a line voltage device form a low voltage controller.
  • Electrical Connections (main) 2-Wire Switching Action DPST. one pole line voltage, the other low voltage or millivoltage.
  • Coil Ratings Current 0.4A.
  • Coil Ratings Voltage 24 Vac.
  • Temperature Range (F) 115 F maximum ambient for 60 Hz. 105 F Max. Ambient for 50 Hz. Temperature Range (C) 46 C maximum ambient for 60 Hz., 41 C maximum ambient for 50 Hz.
  • Dimensions (in.) 5 1/4 in. high x 4 1/4 in. wide x 2 5/16 in. deep.
  • Dimensions (mm) 133 mm high x 108 mm wide x 59 mm deep.
  • Electrical Ratings - Primary Voltage 120V. 50/60 Hz.
  • Approvals, Underwriters Laboratories Inc Listed: File No. E4436, Guide No. XAPX.
  • Approvals, Canadian Standards Association Certified: File No. LR1620.
  • Includes Integral transformer, enclosure.
  • Tradeline Value: Tradeline.
  • Electrical Ratings (Maximum Input) 5.0 W.
  • Electrical Ratings (Primary Voltage) 120V, 50/60 Hz.
  • Contacts Electrical Rating Main Contacts 120 Vac 7.4A AFL. 44.4A ALR. 10A Resistive.
  • Contacts Electrical Rating Main Contacts 240 Vac 3.7A ALF. 22.2A ALR. 6.0A Resistive.
  • Contacts Electrical Rating Secondary Contacts Pilot Duty Rat 50 VA @ 24V.
  • Contacts Electrical Rating Secondary Contacts Dc Rating 1A @ 12 Vdc.
  • Contacts Electrical Rating Secondary Contacts Millvolt Ratin 300 mA min. @ 750 mV.
  • Contacts Electrical Rating Contacts Max. Connected Load 2000 VA (120 Vac to 240 Vac) Electrical Rating: Maximum Input 5.0W.
RA832A1066RA832A1066/U