Product Details
- Voltage24 VAC
- Dimensions5-1/4 x 4-1/16 x 1-15/16 in
- Amperage2 A
- Temperature Range-40 to 175 °F
- Hertz60 Hz
Description
Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.
- Control ignition sequence and gas control operation.
- Generate high voltage potential for main burner ignition.
- Lockout after one trial for ignition if main burner fails to ignite.
- Reset from thermostat after lockout.
- Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less.
- Provide electronic control of direct spark ignition systems used on gas fired furnaces, boilers, and other heating appliances.
- Ignition System Type: Direct Spark Ignition.
- Ignition Sequence: Single trial for main burner ignition (then shut down and lockout).
- Typical Gas Control: VR8205, VR8305.
- Type of Gas: Natural or LP.
- Ignition Source: Internal high voltage spark generator.
- Prepurge: None.
- Ignition Trials To Lockout: 1.
- Maximum Valve Load @ 24 Vac (Amps): 2A.
- Typical Ignition Hardware: Q347A.
- Dimensions: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. long.
- Electrical Ratings: 24 Vac.
- Frequency: 60 Hz.
- Max Ambient Temperature: -40 F to +175 F.
- Includes: Alarm terminal.
- Flame Failure Response Time: 0.8 sec. @ 5.0 microamp.