Product Details
- Voltage24 v
- Size1/2 in
- Hertz50/60 Hz
- Connection TypeNPT
- Temperature Range-40 to 175 °F
- Max Pressure1/2 PSI
- Fuel TypeNatural Gas
Description
The SmartValve System Controls provide easy field replacement of a
wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve System
models. Gas appliance manufacturers use these models in many types of
gas fired heating appliances including central furnaces, residential
boilers, rooftop furnaces, commercial cooking appliances, and unit
heaters. These controls provide intermittent pilot gas ignition
sequencing, pilot flame sensing, and both pilot and main gas control
functions in a single control. They are directly compatible with the
Q3450 or Q3480 Intermittent Pilot burners used with the original
controls on the appliance.
- Suitable
for a wide range of gas-fired appliances including residential
furnaces, roof-top furnaces, residential boilers, unit heaters, infrared
heaters, space heaters and commercial cooking units.
- Replaces SV9500, SV9501 and SV9502 controls as noted below.
- Ignition sequence includes timed trial for ignition.
- Description:
1/2 in. NPT x 1/2 in. NPT Intermittent Hot Surface Pilot Ignition
SmartValve Control with fast-fast opening and 3.4 in. wc pressure
regulator setting.
- Flame Sense: Electrode.
- Type of Gas: Natural.
- Ignition System Type: Intermittent Hot Surface Pilot Ignition.
- Ignition Sequence: Intermittent Pilot.
- Ignition Source: Pilot.
- Ignition Trials To Lockout: Continuous Retry.
- PrePurge: None.
- Body Pattern: Straight-through.
- Opening Characteristics: Fast-Fast Opening.
- Ignition Trial Time (sec): 90 sec.
- Electrical Ratings: 24 Vac.
- Frequency: 60 Hz; 50 Hz.
- Flame Failure Response Time (sec): 1.6 sec @ 3 µA.
- Ambient Temperature Range (F): -40 F to +175 F.
- Ambient Temperature Range (C): -40 C to +79 C.
- Pressure Regulator Setting (psi): 3.4 in. wc.
- Pressure Regulator Setting (kPa): 0.87 kPa.
- Pressure Ratings (psi): 1/2 psi.
- Pressure Ratings (kPa): 3.45 kPa.
- Inlet/Outlet Size (in.): 1/2 in. NPT x 1/2 in. NPT.
- Maximum Capacity (ft³/hr): 200 ft³/hr.
- Maximum Capacity (m³/hr): 5.7 m³/hr.
- Minimum Capacity (ft³/hr): 20 ft³/hr.
- Minimum Capacity (m³/hr): 0.6 m³/hr.
- Maximum Capacity at 1 in. P.D. (ft³/hr): 150 ft³/hr.
- Maximum Capacity at 1 in. P.D. (m³/hr): 4.2 m³/hr.
- Pilot Gas Outlet: Yes.
- Typical Ignition Hardware: Q3450.
- Approvals, American Gas Association IAS: IAS Design Certified: C2030017.
Note: This
product must be installed by a qualified/licensed contractor and set up
with properly calibrated combustion test equipment. Failure to comply
with this could result in substantial property damage, severe personal
injury or death.