Product Details
- Voltage25 VAC
- Stages1
- Used WithCommercial HVAC Equipment, Residential
Description
Furnace Control Board, OEM Replacement, Input Voltage 24V AC, CSA, For Use With Commercial HVAC Equipment, Residential, Replaces Lennox Models 100925-01, 100925-02, 100925-03, 10M93, 32M8801, 56L84, 56L8401, 24L8501, 63K89, 63K8901, 97L4801, 17W9201, 23W5101, 30W2501, 69M0801, 69M1501, 83M001, White Rodgers Models 50A66-843, 50A62-121, 50A66-122, 5066-123, 50A65-121, 50A62-120, 50A62-820, 50A66-123, Includes Circuit Breaker, Fasteners, Mounting Panel, Wire, Wiring Harnesses.
- Includes diagnostic indicator flash codes.
- 3 fan speeds.
- Remote flame sense.
- Humidifier and electronic air cleaner connections (optional).
- Input Voltage: 25 VAC 50 / 60 Hz.
- Maximum Input Current @ 25 VAC: 0.45 amp.
- Valve Relay: 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf.
- Ignitor Relay: 2.0 amp @ 120 VAC 50 / 60 Hz (resistive).
- Inducer Relay: 2.2 FLA ? 3.5 LRA @ 120 VAC.
- Circulator Relay: 14.5 FLA ? 25.0 LRA @ 120 VAC.
- Operating Temperature Range: -40 to +175°F (-40 to +79°C).
- Humidity Range: 5% to 93% relative humidity (non-condensing).
Timing Specifications:
(All times are in seconds unless noted otherwise).
- 21D83M-843.
- Pre-purge: 15.
- Heat delay to fan ON 45.
- Heat delay to fan OFF 60/90/120/180.
- Cool delay to fan ON 2.
- Cool delay to fan OFF 2/45.
- Auto reset 60 minutes.