Product Details
- Power MethodBattery
- Temperature Range32 to 122 °F
- Battery Type(1) 9V Alkaline
- Batteries Included (Yes/No)Yes
- Measurement TypeAmmeter
Description
The mid-size essential clamp meter has virtually every parameter for electrical and thermal HVACR testing in one meter. This auto and manual ranger includes a host of safety features including a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder with detachable leads, and alligator probe tips for easy one-handed testing. As far as ranges go, it has temperature, capacitance, microamps DC for flame diode tests, and everyday electrical ranges for HVACR. Not to mention it is one of the most durable meters in the industry.
Designed specifically for HVACR field service, the SC440 is a digital multimeter that offers specific features and benefits to HVACR field service pros including:
- Volts AC/DC.
- True RMS.
- Inrush current.
- Duty cycle %.
- 400 amps AC.
- Magnetic strap.
- Dual display.
- Temperature F/C.
- Capacitance.
- Microamps DC.
- Frequency via leads and clamp.
- Non-contact voltage.
- 50 Mega Ohm with 0.1 resolution.
- Continuity.
- Diode test.
- Hold.
- Clamp probe holder.
- LCD backlight.
- Low battery indicator.
- Hi-voltage Warning.
Includes:
- SC440 Meter.
- ADLS2 Deluxe Silicone Lead Set with Gold Plated Tips and Removable Sheath.
- ATB1 Wrap Tab Type K Thermocouple.
- ASA2 Short Alligator Lead Extensions.
- Velcro Strap.
- 9V Battery.
- ANC12 Padded Case.
Specifications:
- Display: 5000 count dual display
- Backlight: 60 second duration with auto-off. Blue color. SC440 only.
- Overrange: (OL) or (-OL) is displayed
- Measurement rate: 3.3 times per second, nominal
- Zero: Automatic
- Operating environment: 32°F to 122°F (0°C to 50°C) at <70% relative humidity
- Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
- Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
- Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]
- APO (Auto Power Off): Approx. 30 minutes
- Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
- Battery life: 200 hours typical alkaline (SC420); 100 hours typical alkaline (SC440)
- Low battery indication: Battery icon blinks and “LO.bt” is displayed when the battery voltage drops below the operating level
- Dimensions: 233mm(H) x 79mm(W) x 45mm(D)
- Weight: Approx. 315g including battery
- Altitude: Up to 6562 ft (2000m)
- Overload protection: 600 VDC or 600VAC rms unless otherwise stated
- Test leads: Use UL listed test leads that comply to UL61010-031 rated CATIII 600V or above
- Included test leads are gold-plated and have removeable safety caps